20% OFF shipping at oderzo.it on orders over $79 + up to 10% OFF products
oderzo.it
home > Agilent N9030A PXA X-Series Signal Analyzer, 3 Hz to 3.6 GHz (Option 503) (Pre-Owned) > Agilent N9030A PXA X-Series Signal Analyzer, 3 Hz to 3.6 GHz (Option 503) (Pre-Owned)
download picture
Agilent N9030A PXA X-Series Signal Analyzer, 3 Hz to 3.6 GHz (Option 503) (Pre-Owned)Agilent N9030A PXA X Series Signal Analyzer, 3 Hz to 3. 6 GHz (Option 503) (Pre Owned) Key Features At A Glance Frequency coverage from 3 Hz up to 3. 6, 8. 4, 13. 6, 26. 5, 43, 44, or 50 GHz depending on option (503 through 550) LAN 1000Base T, GPIB (IEEE 488), and USB 2. 0 interfaces for automated test system integration Analysis bandwidth of 10 MHz standard, expandable to 25, 40, or 140 MHz with Options B25, B40, or B1X Noise Floor Extension (NFE)
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Agilent N9030A PXA X-Series Signal Analyzer, 3 Hz to 3.6 GHz (Option 503) (Pre-Owned)

Key Features At A Glance

  • Frequency coverage from 3 Hz up to 3.6, 8.4, 13.6, 26.5, 43, 44, or 50 GHz depending on option (503 through 550)
  • LAN 1000Base-T, GPIB (IEEE-488), and USB 2.0 interfaces for automated test system integration
  • Analysis bandwidth of 10 MHz standard, expandable to 25, 40, or 140 MHz with Options B25, B40, or B1X
  • Noise Floor Extension (NFE) lowers the displayed average noise level for low-level signal measurements
  • RF input connector by option: Type-N female, APC 3.5 mm (Option C35), or 2.4 mm male
  • PowerSuite measurements including channel power, ACP, occupied bandwidth, CCDF, and spectrum emission mask
  • Optional preamplifiers (Options P03 through P50) extend sensitivity across the frequency bands
  • Removable 80 GB solid-state drive with a 1024 x 768 XGA display, 8.4 in diagonal

The Agilent N9030A PXA is an X-Series signal analyzer positioned as a future-ready, evolutionary replacement for an existing high-performance analyzer. It spans frequencies from 3 Hz to as high as 50 GHz depending on the configured frequency option, and is built to reveal new levels of signal detail with outstanding RF performance while refreshing legacy systems with a highly compatible replacement.

The PXA is intended for demanding applications in aerospace, defense, and commercial communications. Its stated value is helping engineers sustain past achievements, enhance current designs, and accelerate future innovations — increasing test throughput and protecting existing system investments as measurement needs grow.

ValueTronics stocks test and measurement equipment in its own 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

Agilent Technologies was spun out of Hewlett-Packard in 1999 as a dedicated test and measurement company. In 2014, Agilent's electronic measurement business was separated again to form Keysight Technologies, which carries the line forward today.

Compare Other Models in This Series

The N9030A PXA is offered as an X-Series signal analyzer family in which frequency reach is set by the chosen frequency option. All configurations share the same 3 Hz low-frequency limit, while the upper frequency extends to 3.6 GHz (Option 503), 8.4 GHz (508), 13.6 GHz (513), 26.5 GHz (526), 43 GHz (543), 44 GHz (544), or 50 GHz (550).

Across the family, the core architecture — PowerSuite measurements, the I/Q analyzer, Noise Floor Extension, and the standard interface set — is consistent. What changes between configurations is primarily the frequency span and the associated RF front-end hardware.

Each pre-owned configuration below is its own dedicated product page with condition-matched pricing. Select the frequency option that matches your application's upper frequency requirement to reach the corresponding page.

Within the family, the configured frequency option determines not only the analyzer's upper frequency but also the available preamplifier coverage and the front-panel RF input connector type.

The configurations differ chiefly in upper frequency limit, which steps from 3.6 GHz through 50 GHz across Options 503 to 550. The standard RF input connector is Type-N female on the 3.6 to 26.5 GHz options (503, 508, 513, 526) and 2.4 mm male on the millimeter-wave options (543, 544, 550); an APC 3.5 mm input is available via Option C35 with Option 526.

Preamplifier coverage also tracks the frequency option: Options P03 through P50 extend from 9 kHz up to 3.6, 8.4, 13.6, 26.5, 43, 44, or 50 GHz respectively. See the comparison table for the per-option frequency ranges, connector types, and related differences.

Model Max Frequency Min Frequency RF Input Connector
N9030A 3.6 GHz 3 Hz Type-N female

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Frequency and Time
Frequency range (DC coupled) 3 Hz to maximum frequency of instrument (option dependent; up to 50 GHz)
Frequency range (AC coupled) 10 MHz to maximum frequency of instrument
Precision frequency reference aging rate ± 1 x 10–7 / year; ± 1.5 x 10–7 / 2 years
Temperature stability (20 to 30 °C) ± 1.5 x 10–8
Temperature stability (full temperature range) ± 5 x 10–8
Achievable initial calibration accuracy ± 4 x 10–8
Marker frequency counter resolution 0.001 Hz
Frequency span range 0 Hz (zero span), 10 Hz to maximum frequency of instrument
Frequency span resolution 2 Hz
Sweep time range (span = 0 Hz) 1 µs to 6000 s
Sweep time range (span ≥ 10 Hz) 1 ms to 4000 s
Sweep trigger sources Free run, line, video, external 1, external 2, RF burst, periodic timer
Sweep (trace) point range 1 to 40001
Resolution bandwidth range (–3.01 dB) 1 Hz to 3 MHz (10 % steps), 4, 5, 6, 8 MHz
RBW selectivity (–60 dB/–3 dB) 4.1:1 nominal
EMI bandwidth (CISPR compliant) 200 Hz, 9 kHz, 120 kHz, 1 MHz (Option EMC required)
EMI bandwidth (MIL STD 461E compliant) 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz (Option EMC required)
Video bandwidth range 1 Hz to 3 MHz (10 % steps), 4, 5, 6, 8 MHz, and wide open (labeled 50 MHz)
Maximum analysis bandwidth (standard) 10 MHz
Maximum analysis bandwidth (Option B25) 25 MHz
Maximum analysis bandwidth (Option B40) 40 MHz
Maximum analysis bandwidth (Option B1X) 140 MHz
Amplitude Accuracy and Range
Measurement range Displayed average noise level (DANL) to maximum safe input level
Input attenuator range (3 Hz to 50 GHz) 0 to 70 dB in 2 dB steps
Electronic attenuator (Option EA3) range 0 to 24 dB, 1 dB steps; full range (mechanical + electronic) 0 to 94 dB, 1 dB steps
Maximum safe input — average total power +30 dBm (1 W)
Maximum safe input — peak pulse power +50 dBm (100 W), < 10 µs pulse width, < 1 % duty cycle, input attenuation ≥ 30 dB
Maximum DC (DC coupled) ± 0.2 Vdc
Maximum DC (AC coupled) ± 100 Vdc
Display range (log scale) 0.1 to 1 dB/division in 0.1 dB steps; 1 to 20 dB/division in 1 dB steps (10 divisions)
Scale units dBm, dBmV, dBµV, dBmA, dBµA, V, W, A
Total absolute amplitude accuracy at 50 MHz ± 0.24 dB (± 0.19 dB 95th percentile)
Reference level range (log scale) –170 to +30 dBm in 0.01 dB steps
Reference level range (linear scale) 707 pV to 7.07 V with 0.11 % (0.01 dB) resolution
Display scale fidelity (–10 to –80 dBm input mixer level) ± 0.10 dB total (± 0.04 dB typical)
Trace detectors Normal, peak, sample, negative peak, log power average, RMS average, voltage average
Preamplifier gain (9 kHz to 3.6 GHz) +20 dB nominal
Preamplifier gain (3.6 to 26.5 GHz) +35 dB nominal
Preamplifier gain (26.5 to 50 GHz) +40 dB nominal
Displayed Average Noise Level (DANL) — Preamp off, Normal / LNP enabled (input terminated, 0 dB attenuation, 20 to 30 °C)
3 Hz to 9 kHz –146 dBm
9 to 100 kHz –150 dBm
100 kHz to 1 MHz –155 dBm
1 to 10 MHz –155 dBm
10 MHz to 1.2 GHz –153 dBm
1.2 to 2.1 GHz –152 dBm
2.1 to 3.0 GHz –151 dBm
3.0 to 3.6 GHz –147 dBm / –153 dBm
3.5 to 4.2 GHz –150 dBm / –155 dBm
4.2 to 8.4 GHz –149 dBm / –155 dBm
8.3 to 13.6 GHz –145 dBm / –152 dBm
13.5 to 16.9 GHz –143 dBm / –151 dBm
16.9 to 20.0 GHz –137 dBm / –150 dBm
Dynamic Range
1 dB gain compression — 20 to 40 MHz (max power at input mixer) –3 dBm (0 dBm typical)
1 dB gain compression — 40 to 200 MHz +1 dBm (+3 dBm typical)
1 dB gain compression — 200 MHz to 3.6 GHz +3 dBm (+5 dBm typical)
1 dB gain compression — 3.6 to 16 GHz +1 dBm (+4 dBm typical)
1 dB gain compression — 16 to 26.5 GHz –1 dBm (+2 dBm typical)
Third-order intermodulation (TOI) — 0.6 to 1.1 GHz +20 dBm (+22 dBm typical)
Third-order intermodulation (TOI) — 1.1 to 3.6 GHz +21 dBm (+23 dBm typical)
Third-order intermodulation (TOI) — 3.5 to 8.4 GHz +15 dBm (+22 dBm typical)
Third-order intermodulation (TOI) — 8.3 to 13.6 GHz +15 dBm (+23 dBm typical)
Second harmonic distortion (SHI) — 0.1 to 1.8 GHz +45 dBm
Second harmonic distortion (SHI) — 1.75 to 2.5 GHz +62 dBm / +80 dBm
Residual responses (input terminated, 0 dB attenuation, 200 kHz to 8.4 GHz) –100 dBm
Phase Noise — typical (CF = 1 GHz, 20 to 30 °C)
10 Hz offset –75 dBc/Hz nominal
100 Hz offset –100 dBc/Hz typical
1 kHz offset –125 dBc/Hz typical
10 kHz offset –132 dBc/Hz typical
30 kHz offset –132 dBc/Hz typical
100 kHz offset –131 dBc/Hz typical
Important: Specifications associated with Options 543, 544, and 550 (43, 44, and 50 GHz frequency ranges) are either preliminary or not yet available.
Important: Option C35 (APC 3.5 mm RF input connector) is available with Option 526 only.
Important: LNP (Low Noise Path) requires Option LNP; at frequency bands above 3.6 GHz, Preamp “On” supersedes “LNP enabled” — LNP cannot operate simultaneously with the preamp.
Important: When Option MPB (microwave preselector bypass) is installed and enabled, some aspects of the analyzer performance change; refer to the PXA specification guide for details.
Important: This data sheet is a summary of the complete specifications and conditions; the complete PXA Signal Analyzer Specification Guide is available from Agilent.
Recommended pairing: for deep waveform capture, use the Agilent 89600B vector signal analysis (VSA) software or the N9064A, as noted in the I/Q analyzer data acquisition specifications.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Agilent N9030A PXA X-Series Signal Analyzer, 3 Hz to 3.6 GHz (Option 503) (Pre-Owned)

Item no : 1310688821
sold recently : Login >>
US$ 17485.50
Pay in 4 interest-free payments of $4371.38 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 23 - Jun 28

Enjoy 20% off shipping

US$ 17485.50

1-11

US$ 15736.95

12-35

US$ 12239.85

36-59

US$ 10491.30

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches